SPECIFICATIONS
PUMP | ||
Liquid Handled | Type of liquid | Clean water |
Max temperature [°C] | 60 | |
110 (2CDXH and 2CDXHS) | ||
Min temperature [°C] | -10 | |
Maximum working pressure [MPa] | 0.8 | |
Construction | Impeller | Closed centrifugal type (Twin) |
Shaft seal type | Mechanical seal | |
Bearing | Sealed ball bearing | |
Pipe Connection | Suction | G 1¼, G 1½ (2CDX200) |
Discharge | G 1 | |
Material | Casing | AISI 304 |
Impeller | AISI 304 | |
Casing cover | AISI 304 | |
Shaft seal | Ceramic/Carbon/NBR (2CDX) | |
Ceramic/Carbon/FPM (2CDXH) | ||
SiC/SiC/FPM (2CDXHS) | ||
Shaft | AISI 304 (Wet extension) | |
Bracket | Aluminium (up to 1.5 kW included) Cast iron (2.2 kW and above ) | |
Diffuser | AISI 304 | |
Applicable standard of test | ISO 9906 – Annex A |
MOTOR | |||
Type | Electric – TEFC | ||
Single Phase Three Phase | |||
No. of Poles | 2 | ||
Rotation speed [min-1] | » 2800 | ||
Insulation Class | Class F | ||
Protection degree | IP 55 | ||
Power rating | [kW] | 0.75 ÷ 1.5 | 0.75 ÷ 4 |
[HP] | 1 ÷ 2 | 1 ÷ 5.5 | |
Frequency [Hz] | 50 | ||
Voltage [V] | 230 ±10% | 230/400 ±10% | |
Capacitor | Built in | – | |
Over load protection | Built in | Provided by the user | |
Casing material | Aluminium | ||
Base material/motor support | Aluminium | ||
Dimensions of cable entry | PG 11, PG 13.5, PG 16 (see dimension page 400) |
Type pumps | Power | Q=Capacity | |||||||||
[kW] |
[HP] |
l/min 20 | 40 | 60 | 80 | 120 | 150 | 180 | 210 | ||
Single Phase | Three Phase | m³/h 1.2 | 2.4 | 3.6 | 4.8 | 7.2 | 9.0 | 10.8 | 12.6 | ||
H=Total manometric head in meters | |||||||||||
2CDXM 70/10 | 2CDX 70/10 | 0.75 | 1 | 38.5 | 35.3 | 31.5 | 27 | – | – | – | – |
2CDXM 70/12 | 2CDX 70/12 | 0.9 | 1.2 | 44.5 | 40.3 | 35.5 | 30 | – | – | – | – |
2CDXM 70/15 | 2CDX 70/15 | 1.1 | 1.5 | 52.5 | 48 | 42.8 | 36.5 | – | – | – | – |
2CDXM 70/20 | 2CDX 70/20 | 1.5 | 2 | 60 | 55.6 | 50.4 | 44 | – | – | – | – |
2CDXM 120/15 | 2CDX 120/15 | 1.1 | 1.5 | – | 42 | 41 | 39.5 | 35 | 30 | – | – |
2CDXM 120/20 | 2CDX 120/20 | 1.5 | 2 | – | 51.5 | 49.5 | 47.4 | 41.8 | 36.5 | – | – |
– | 2CDX 120/30 | 2.2 | 3 | – | 59 | 57 | 54.6 | 49.2 | 44 | – | – |
– | 2CDX 120/40 | 3 | 4 | – | 68.5 | 66.5 | 64 | 58 | 52 | – | – |
– | 2CDX 200/30 | 2.2 | 3 | – | – | 52 | 50.8 | 48.1 | 45.5 | 42.7 | 39.5 |
– | 2CDX 200/40 | 3 | 4 | – | – | 62.5 | 61.1 | 58 | 55.2 | 52.3 | 49 |
– | 2CDX 200/50 | 3.7 | 5.5 | – | – | 71.5 | 70.1 | 67 | 64.3 | 61.2 | 57.5 |