Máy bơm làm mát LKW
Standard specification
| Used liquid | Property of liquid | Water-soluble coolant liquid |
| Temperature | 0 to 60°C (No frozen liquid) | |
| Allowable kinematic viscosity | 1mm2/s | |
| Installation location | Indoor | |
| Ambient temperature: 0 to 40 °C, RH 85% or below (no condensation), Height above sea level: 1000m or less, | ||
| Place not exposed to direct sunlight, Place in an area free of corrosive or explosive gas or vapor. | ||
| Material | Suction cover · Discharge casing | FC200 |
| Intermediate casing | ARLS ※ +SUS304 | |
| Impeller | ARLS ※ | |
| Shaft | S35C | |
| Shaft seal structure | Non-seal (mechanical seal-less) | |
| Motor | Power source | 3-phase 50/60/60 Hz, 200/200/220 V |
| Type | Totally enclosed fan-cooled, indoor type | |
| Protection method | IP44 | |
| Thermal class | F | |
| Rating | Continuous | |
| Number of poles | 2P | |
| Paint color | Munsell N1.5 | |

- Specification table
| Bore diameter (mm) | Frequency (Hz) | Type | Rated voltage (V) | Output (kW) | Rated current (A) | Starting current (A) | Discharge rate (L/min) | Total head (m) |
| 20 | 50 | LKW2006-52.0-e | 200 | 2.2 | 9.3 | 84 | 20~70 | 100~42 |
| LKW2009-53.0-e | 3.0 | 14.8 | 180 | 20~70 | 150~65 | |||
| LKW2012-54.0-e | 4.0 | 16.0 | 179 | 20~70 | 200~90 | |||
| LKW2009-53.0-D-e | 3.0 | 14.8 | 180 | 20~70 | 300~130 | |||
| LKW2012-54.0-D-e | 4.0 | 16.0 | 179 | 20~70 | 400~180 | |||
| 60 | LKW2006-62.0-e | 200/220 | 2.2 | 8.4/7.9 | 73/80 | 20~70 | 100~43 | |
| LKW2009-63.0-e | 3.0 | 12.0/12.1 | 152/167 | 20~70 | 150~67 | |||
| LKW2012-64.0-e | 4.0 | 15.0/14.0 | 152/173 | 20~70 | 200~90 | |||
| LKW2009-63.0-D-e | 3.0 | 12.0/12.1 | 152/167 | 20~70 | 300~134 | |||
| LKW2012-64.0-D-e | 4.0 | 15.0/14.0 | 152/173 | 20~70 | 400~180 |